Posted: admin on Aug 31 | Normal Air to Water Heat Pump, Products
A Good Solution Of Energy Saving
New generation heat pump product developed with the advanced heating technologies. Completely and strictly tested with our European partners to make sure the efficiency quality. Especially for cold areas. The working ambient is -15 ºC to 45 ºC and keep supply of warm water from 35 ºC to 60 ºC.Well known components Copeland, Siemens, Danfoss, Wilo,providing the most reliability to the customers.
Outstanding Performance
High efficiency and energy saving. Maxmum outlet water temperature up to 60 ºC. Expansion valve keeps the most suitable refrigerant flow in any case. Water flow protection, pressure protection, temp protection keep the system safety.
High Quality And Reliability
Stainless steel plate heat exchanger with maximum pressure 40 bar. 100% stainless water circuit to keep water clean. Microprocessor control and error alarm and display . Electric protection class IPX4. Compact design,easy installation and maintenance.
Flexible Installation
Our heat pumps are suitable for many different heating systems to heat the house or produce hot water. Connected with an exist boiler or replace the old electric/ gas/oil heater. Installed for house heating and hot water supplying. Installed together with a solar heating sysytem. Installed for swimming pool heating (closed water circuit).
House Heating And Warm Water Supply

Accessories (optional) Circulation pump
LCD wired controller

Main components

Product Description
Our air to water heat pump is a new generation heat pump prduct developed with the most advanced heating technologies. The heat pump utilizeds the energy from surrounding air and converts it to the hot water for house air conditioning heating cooling and domestic hot water supply. The whole range of this heat pump is strictly tested with our European partners to make sure the best quality for European market. Especially for super low temperature area. The working abient is -15 ºC to 45 ºC and keep supply of warm water from 35 ºC to 60 ºC.
We select the best well known components for our heat pump such as Copeland compressor, Siemens, Danfoss, Wilo. It provide the most reliability to our customers.
Striking characters distinguish from other products
1.High efficiency and energy saving
2.Environmental friendly refrigerant
3.Keep working in super low temperature
4.Using step fan motor to make the accurate control
5.Water flow protection, pressure prtection, temp protection keep the the system safety.
Other characters
1.Stainless steel plate heat exchanger with maximum pressure 40 bar
2.100% stainless water circuit to keep water clean
3.Microprocessor control and error alarm and display
4.Electric protection class IPX4
5.Compact design for good looking, easy installation and maintenance
Air to Water Heat Pumps Specification | |||||||||||
Models (1) | RJ-35H/N1 | COP | RJ-35H/N1a | COP | RJ(P)-55H/N1 | COP | RJ(P)-80H/N1 | COP | RJ-110H/SN1 | COP | |
Heating capacity(2) /Power input (KW) | at A20/W35ºC (3) | 4.6/1.09 | 4.22 | 4.6/1.15 | 4 | 7.04/1.68 | 4.19 | 10.62/2.43 | 4.37 | 14.41/3.38 | 4.26 |
at A20/W50ºC (3) | 4.5/1.4 | 3.2 | 4.5/1.4 | 3.21 | 6.8/2.15 | 3.16 | 10.25/3.12 | 3.29 | 14.0/4.29 | 3.26 | |
at A15/W50ºC (3) | 4.1/1.35 | 3.0 | 4.1/1.35 | 3.04 | 6.25/2.07 | 3.02 | 9.34/3.0 | 3.11 | 12.76/4.13 | 3.09 | |
at A7/W35ºC (3) | 3.6/0.98 | 3.7 | 3.6/0.98 | 3.67 | 5.5/1.5 | 3.67 | 8.2/2.18 | 3.76 | 11.2/3.0 | 3.73 | |
at A7/W45ºC (3) | 3.58/1.15 | 3.1 | 3.58/1.15 | 3.11 | 5.47/1.76 | 3.11 | 8.15/2.56 | 3.18 | 11.14/3.52 | 3.16 | |
at A7/W50ºC (3) | 3.4/1.26 | 2.7 | 3.4/1.26 | 2.7 | 5.24/1.92 | 2.73 | 7.8/2.76 | 2.83 | 10.8/3.8 | 2.84 | |
at A2/W35ºC (3) | 3.2/0.95 | 3.4 | 3.2/0.95 | 3.37 | 4.89/1.45 | 3.37 | 7.29/2.11 | 3.45 | 9.96/2.91 | 3.42 | |
at A2/W50ºC (3) | 3.05/1.23 | 2.5 | 3.05/1.23 | 2.48 | 4.66/1.88 | 2.48 | 6.95/2.74 | 2.54 | 9.49/3.77 | 2.52 | |
at A0/W45ºC (3) | 2.85/1.12 | 2.5 | 2.85/1.12 | 2.54 | 4.35/1.71 | 2.54 | 6.49/2.49 | 2.61 | 8.87/3.43 | 2.59 | |
at A-7/W45ºC (3) | 2.2/1.1 | 2.0 | 2.2/1.1 | 2 | 3.36/1.68 | 2 | 5.01/2.45 | 2.04 | 6.84/3.37 | 2.03 | |
at A-7/W50ºC (3) | 2.15/1.18 | 1.8 | 2.15/1.18 | 1.82 | 3.28/1.81 | 1.81 | 4.9/2.62 | 1.87 | 6.69/3.61 | 1.85 | |
colling capacity/Power input(KW) | at A35/W7ºC (3) | 3.3/1.15 | 2.9 | 3.3/1.15 | 2.9 | 5.1/1.76 | 2.9 | 7.6/2.56 | 2.97 | 10.5/3.52 | 2.98 |
Max.power input (KW) | 1.8 | 1.8 | 2.6 | 3.8 | 5.5 | ||||||
Max.currentt (A) | 8.2 | 8.2 | 12.5 | 17.4 | 9 | ||||||
Electric supply | 230V-50Hz | 400V-3N-50Hz | |||||||||
Max.water temperature (ºC) | 60 | ||||||||||
Running temperature range (ºC) | -15~43 | ||||||||||
Refrigerant circuit | Refrigerant | R407C | |||||||||
compressor(s) | Rotary | Rotary | Rotary | Rotary | Scroll | ||||||
Heat exchange | High efficiency fin-tube heat exchanger | ||||||||||
Fan motor (W) | 35 | 80 | 80 | 150 | 250 | ||||||
Air flow (m3/h) | 2000 | 3000 | 3000 | 4500 | 6500 | ||||||
Water circuit | Heat exchanger | Stainless steel plate heat exchanger | |||||||||
In/Out pipe | DN20(3/4”) | DN20(3/4”) | DN20(3/4”) | DN25(1”) | DN25(1”) | ||||||
Water flow (m3/h) | >=0.6 | >=0.6 | >=0.8 | >=1.2 | >=1.6 | ||||||
permitted pressure | =<0.8MPa | ||||||||||
Unit dimensions WxHxD (mm) | 772×540x254 | 850×605x290 | 850×605x290 | 850×850x310 | 970×960x360 | ||||||
Pacage dimensions WxHxD (mm) | 790×650x360 | 1010×695x430 | 1010×695x430 | 1010×875x430 | 1100×1100x440 | ||||||
Net weight (Kg) | 45 | 52 | 65 | 81 | 110 | ||||||
Gross weight (Kg) | 47 | 57 | 68 | 86 | 118 | ||||||
Noise level (dB(A)) | 51 | 51 | 52 | 54 | 56 | ||||||
| Electric heater(optional) (4) (KW) | |||||||||||
Air to Water Heat Pumps Specification | ||||||||||
Models (1) | RJ(P)-160H/SN1 | COP | RJ(P)-220H/SN1 | COP | RJ(DP)-280H/SN1 | COP | RJ(DP)-560H/SN1 | COP | RJ(DP)-680H/SN1 | |
Heating capacity(2) /Power input (KW) | at A20/W35ºC (3) | 21.51/5.12 | 4.2 | 28.7/6.9 | 4.16 | 36.5/9.1 | 4.01 | 71.68/17.72 | 4.05 | 86.95/21.99 |
at A20/W50ºC (3) | 20.8/6.5 | 3.2 | 28.0/8.58 | 3.26 | 35.4/11.15 | 3.19 | 70/21.66 | 3.24 | 85/26.88 | |
at A15/W50ºC (3) | 18.79/6.34 | 2.96 | 25.6/8.25 | 3.1 | 32.2/10.7 | 3.01 | 63.78/20.87 | 3.07 | 77.44/25.9 | |
at A7/W35ºC (3) | 16.5/4.6 | 3.59 | 22.4/6.0 | 3.73 | 28.3/7.8 | 3.63 | 56/15.15 | 3.71 | 68/18.8 | |
at A7/W45ºC (3) | 16.41/5.4 | 3.04 | 22.28/7.04 | 3.16 | 28.14/9.15 | 3.08 | 55.69/17.78 | 3.15 | 67.62/22.06 | |
at A7/W50ºC (3) | 15.7/5.9 | 2.66 | 21.3/7.7 | 2.77 | 27.2/10 | 2.72 | 52.89/19.48 | 2.73 | 64.22/24.17 | |
at A2/W35ºC (3) | 14.67/4.46 | 3.29 | 19.91/5.82 | 3.42 | 25.16/7.56 | 3.33 | 49.78/14.69 | 3.41 | 60.44/18.22 | |
at A2/W50ºC (3) | 13.98/5.77 | 2.42 | 18.98/7.53 | 2.52 | 23.98/9.79 | 2.45 | 47.44/19.01 | 2.5 | 57.61/23.6 | |
at A0/W45ºC (3) | 13.06/5.26 | 2.48 | 17.73/6.86 | 2.58 | 22.4/8.91 | 2.51 | 44.33/17.31 | 2.56 | 53.83/21.49 | |
at A-7/W45ºC (3) | 10.08/5.16 | 1.95 | 13.69/6.73 | 2.03 | 17.29/8.76 | 1.97 | 34.22/17.01 | 2.01 | 41.56/21.10 | |
at A-7/W50ºC (3) | 9.85/5.54 | 1.78 | 13.38/7.22 | 1.85 | 16.9/9.39 | 1.8 | 33.44/18.24 | 1.84 | 40.61/22.64 | |
colling capacity/Power input(KW) | at A35/W7ºC (3) | 15/5.4 | 2.78 | 20/7.04 | 2.84 | 26.3/9.15 | 2.87 | 52.5/17.1878 | 3.07 | 66/22.06 |
Max.power input (KW) | 8 | 10.4 | 13.5 | 26.3 | 32.7 | |||||
Max.currentt (A) | 13 | 17 | 22 | 42.8 | 53.1 | |||||
Electric supply | 400V-3N-50Hz | |||||||||
Max.water temperature (ºC) | 60 | |||||||||
Running temperature range (ºC) | -15~43 | |||||||||
Refrigerant circuit | Refrigerant | R407C | ||||||||
compressor(s) | Scroll | Scroll | 2xScroll | 4xScroll | 4xScroll | |||||
Heat exchange | High efficiency fin-tube heat exchanger | |||||||||
Fan motor (W) | 150×2 | 250×2 | 700 | 700×2 | 850×2 | |||||
Air flow (m3/h) | 9000 | 12000 | 14500 | 28000 | 32000 | |||||
Water circuit | Heat exchanger | Stainless steel plate heat exchanger | Double pipe heat exchangr | |||||||
In/Out pipe | DN32(1-1/4″) | DN32(1-1/4″) | DN40(1-1/2″) | DN50(2″) | DN50(2″) | |||||
Water flow (m3/h) | >=2.2 | >=3.0 | >=3.5 | >=7.0 | >=9.0 | |||||
permitted pressure | =<0.8MPa | |||||||||
Unit dimensions WxHxD (mm) | 970×1258x380 | 970×1500x360 | 1265×1760x1020 | 1950×1930x1100 | ||||||
Pacage dimensions WxHxD (mm) | 1070×1410x450 | 1100×1640x440 | 1415×1890x1200 | 2200×2200x1350 | ||||||
Net weight (Kg) | 140 | 180 | 300 | 560 | 620 | |||||
Gross weight (Kg) | 150 | 195 | 325 | 600 | 660 | |||||
Noise level (dB(A)) | 56 | 57 | 59 | 61 | 62 | |||||
Electric heater(optional) (4) (KW) | 9 | 20 | 5 | |||||||
(1)The data of stable running condition(when defrosting,the average heating capacity reduces about 10% compare to corresponding data)
(2)Surrounding air temperature/outlet water temperature
(3)The electric heater must be equipped outside for the models fom RJ-35H/N1 to RJ(P)-220H/SN1
Chengda Eco Tech is a professional heat pump manufacturer with Spain technology background
No comments